- Schlage Cm993 Manual Downloads
- Schlage Cm993 Manual
- Schlage Cm993 Manual User
- Schlage Cm993 Manual Transmission
- Schlage Cm993 Manual Software
products
Download Schlage cm993 manual.pdf Download Lcdc study guide.pdf More manual PDF Files: Download Manual for carrier chiller 30xa 1002.pdf 2 / 3. Cobra KC9000 PIN/iButton SNAP Compatible trim with - Since this is a discontinued item, if lock becomes defective. 3. Schlage. Schlage Utility Software User's Guide The Schlage Utility Software (SUS) is a software application that runs on a Windows CE based handheld device. It is used to transfer data files between the access control software and locks and controllers. Quick Start To begin using the SUS, review the following topics. Schlage M490DEP Manuals & User Guides. User Manuals, Guides and Specifications for your Schlage M490DEP Locks. Database contains 1 Schlage M490DEP Manuals (available for free online viewing or downloading in PDF): Installation instructions and use.
- CM locks from Schlage are computer managed, stand alone locking systems that are designed for robust, flexible access control in both retrofit and new construction installations. Schlage CM stand alone locks provide many of the features of an online access control system, but without the heavy investment associated with networked systems.
- Service manual, honda crf450r service manual 2003, petrol engine guide, psychology bernstein study guide, manuals for john deere mx6, schlage cm993 manual, interactive study guide houghton mifflin fourth grade, 195432 briggs manual, 2015 hyundai hit 15s manual, manual nissan truck fd6, singer psw.
Support
View All SupportL Series Grade 1 Mortise Lock
The L Series mortise lock offers strength and security for almost any commercial application.
Unity pro 5 5 0f3 download free.
Unity pro 5 5 0f3 download free.
The Schlage L Series has long been the benchmark for mortise locks. The L Series is more than strength and security – it offers tremendous flexibility to allow it to meet the needs of most every application. Over 55 functions, 35 lever and knob designs, eight different roses and escutcheons, and a multitude of prep options are just the beginning.
180 degree visibility indicators, advanced motor-driven electrified functions, a universal lock case that supports 10 different functions, and the ability to suite across tubular, exit device, and multipoint locks allow the Schlage L Series to integrate seamlessly into any environment.
In accordance with California PROP65 -
WARNING: Cancer & Reproductive Harm www.P65Warnings.ca.gov
Security
- Exceeds ANSI/BHMA Grade 1 Security and Operational standards
- Deadbolt functions include anti-saw pin in bolt to prevent cut-through
- Security blocking hub prevents lock picking by removing levers
Function availability and compatibility
- 55+ standard functions (custom functions are also available)
- Universal lock case allows 10 functions to be created from a single lock body
- Electrified locks auto detect 12V/24V DC, have customer-selectable EL/EU, and offer advanced features like: RX, DPS, latchbolt monitor and deadbolt monitor for application flexibility while offering leading energy efficiency
Aesthetics
- 14 finishes
- 33 lever, two knob, five rose and three escutcheon designs
- Locking lever bushing eliminates exposed screws on inside levers
- All levers suite with Von Duprin exit devices, along with related L Series products LE, LM9200, LM9300 and LT
Available options
- Exclusive 180° visibility indicator
- Vandlgard® free-wheeling outside trim option is available on most functions, including electrified
- Expansive options portfolio, including different door thickness, finish/trim combinations, tactile warning, anti-microbial coatings, etc.
- New Gold Standard ligature resistant trim for behavioral health applications
In accordance with California PROP65 -
WARNING: Cancer & Reproductive Harm www.P65Warnings.ca.gov
View the Schlage L Series catalog for descriptions of all available functions.
In accordance with California PROP65 -
WARNING: Cancer & Reproductive Harm www.P65Warnings.ca.gov Skytrack service manual.
View the Schlage L Series catalog to see all specifications and certifications.
- Meets BAA (Buy American Act)
- L9000: tested and certified under ANSI/BHMA A156.13, Grade 1 Security and Operational
- UL listed for 3-hour fire door (except L9076 and L9077)
- With interchangeable core cylinders: Grade 2 security
- With concealed shell cylinder: A156.13 Grade 1 operational and security
- ANSI/ASTM F476-76 Grade 40, UL listed
- L400: tested and certified under ANSI/BHMA A156.36 Grade 1
- California Referenced Standards Code: all levers with a return to door of 1/2' (64 mm) or less comply
- UL/cUL listed for A label single doors, 4' x 10' and pairs 8' x 10'; letter F and UL symbol on latch front indicate listing
- Electrified functions are UL19X listed for single-point locking applications
- UL437 listed locking cylinder optional: specify Primus 20-500 Series cylinder
- Miami-Dade NOA's and Florida Building Commission Listings
- Meet ADA requirements
In accordance with California PROP65 -
WARNING: Cancer & Reproductive Harm www.P65Warnings.ca.gov
Technical resources
Don't see the document you're looking for?
Visit the Document Library for the full selection.
In accordance with California PROP65 -
WARNING: Cancer & Reproductive Harm www.P65Warnings.ca.gov
Schlage Cm993 Manual Downloads
Download Installation instructions and use of Schlage M490DE Locks for Free or View it Online on All-Guides.com. This version of Schlage M490DE Manual compatible with such list of devices, as: M490DE, M490DE-2, M490DEP, M490DEP-2
Brand: Schlage
Category: Locks
Type: Installation instructions and use
Model: Schlage M490DE , Schlage M490DE-2 , Schlage M490DEP , Schlage M490DEP-2
Pages: 12
Features
Unlocking is delayed 15
Automatic Voltage Selection
12VDC or 24VDC when power
Fire Unlock
unlock the magnet immediately.
Allows use of an auxiliary switch
button.
Activates external alarm, when
*Indicators
*Magnetic Bond Sensor (MBS)
magnet and armature. It can be
with an LED.
Indicates whether door is open
in conjunction with the MBS.
Relock time can be changed.
*Door Prop Timer
amount of time a door can be
sounds. Range is 0 - 150
* Plus Version Only
M490DE (Single Lock Basic)
Voltage Selection
Basic features + Magnetic Bond
Switch (DPS), Relock Time
Indicators
Double lock with same features
M490DEP-2 (Double Lock Plus)
as the Plus single lock
• BOCA is a Plus only lock option.
see page 12 for operational
UL Requirements
• Units shall not impair operation of panic hardware mounted on door.
• Units shall not impair intended operation of an emergency exit.
• Not to be used without UL approved latching hardware.
• Units/Models are intended to be connected to UL Listed Equipment, not
intended for Burglar or Fire Alarm Initiating or Indicating Devices.
• Wiring methods shall be in accordance with the National Electrical Code,
• This device complies with part 15 of FCC rules.
1. This device may not cause harmful interference.
2. This device must accept any interference received, including any
interference that may cause undesired operation. Changes or
modicationsnotexpresslyapprovedbypartyresponsibleforcompliance
Electrical Specifications
M490DE
M490DE-2
Input Current @ 12VDC Input.75ADC1.25ADC
Holding Force Per Door Leaf1500 lbs.1500 lbs.
Wire Gauge and Length Specifications
Single LockDouble lock
![Schlage cm993 manual pdf Schlage cm993 manual pdf](https://i.pinimg.com/originals/bb/fd/23/bbfd23907b24804f352791920949a504.jpg)
141000 feet4000 feet500 feet2000 feet
Warnings and Cautions
Warnings indicate potentially hazardous conditions, which if not
avoided or corrected, may cause death or serious injury.
Cautions indicate potentially hazardous conditions, which if
not avoided or corrected, may cause minor or moderate injury.
Pre-Installation Considerations
• Use ONLY the hardware provided for mounting this product
Schlage Cm993 Manual
(NOTE: Non-standard Door thickness may require different sex nut
hardware-seespecicinstructionsforrequiredhardware).
• Follow the installation procedure as described in this manual.
• Check door thickness. If the door is not 1Cv” thick, a different sex nut
will be required. Contact customer service at 1-877-671-7011.
Schlage Cm993 Manual User
• Check door header. A minimum 2Cv”thick,atsurfaceisneededto
securely mount all screws for the magnet. If you do not have the
requiredsurface,youwillneedllerplatesand/oranglebracketsto
Contact customer service at 1-877-671-7011.
Header: At least